1746 NI8 PDF

Allen-Bradley NI8 I/O Module, Analog, 8 Channel Input, 24VDC. Allen- Bradley NI8 I/O Module, Mfr Number: NI8. Rexel Part Number: The NI8 analog I/O module contains 8 inputs (-+10V DC, -+20mA). The backplane current load of NI8 is mA at 5V DC or mA at 24V DC. NI8 Low Price Guarantee! Allen Bradley – Rockwell Automation SLC ALBNI8 New, Repair and Reman Parts. Ships Fast and 2 YR Warranty.

Author: Goltibar Mazugrel
Country: Kenya
Language: English (Spanish)
Genre: Video
Published (Last): 27 March 2004
Pages: 407
PDF File Size: 10.59 Mb
ePub File Size: 11.11 Mb
ISBN: 591-9-61325-620-7
Downloads: 11578
Price: Free* [*Free Regsitration Required]
Uploader: Kashakar

It has a Bandwidth of Hertz and an Update Time of 6 milliseconds. Register a new account.

Some of the channels are scaled to and others are scaled to Care should be taken to avoid connecting 176 voltage source to a current input module. The NI8 module has an 8-Channel input with an isolated backplane. Posted 6 Aug It performs continuous autocalibration and has an isolation voltage of Volts DC and Volts AC, tested for 60 seconds.

What publication did this come from? Can this module be purchased with a warranty? In Stock Ships Today. It is a high-resolution analog input module with high-density components and it can be configured by the user with software.

Related Posts (10)  HARPERS BIOCHEMISTRY 29TH EDITION PDF

Wiring Input Devices to the NI8. At one end of the cable, twist the drain wire and foil shield together.

SLC500 PLC i/p module,1746-NI8 8 i/p

Started by gromit5 Aug For troubleshooting and diagnostics, it has 9 green LED status indicators. The cable has a maximum loop impedance of 40 Ohms at the voltage source and Ohms at the current source. Sign In Sign Up. Share this post Link to post Share on other sites. Connect the signal wires and shield drain wire to the NI8 terminal block or.

At the other end of the cable, cut the drain wire and foil shield back to the cable. The NI8 module uses programmable filter frequencies with a low-pass digital filter ni88 input filtering. Please help me interpret the scaling of my NI8 inputs. SLC Module Type: Posted 5 Aug Sign up for a new account in our community. It has a common-mode voltage ranging from to 10 Volts with a maximum of 15 Volts between any two terminals.

Posted 8 Aug Repeat steps 1 through 6 for each channel on nl8 module. After the analog input module is properly installed in the chassis, follow the wiring procedure below using Belden cable. Sign in Already have an account? Trim the signal wires to 50 mm 2 inch lengths.

NI8 Analog Input Module | SLC In-Stock. Ships Today – Santa Clara Systems

When assessing an existing program, all analog inputs are set up as documented, but they use different raw values when scaling e. The channels are set up as follows: You need to be a member in order to leave a comment. Connect the other end of the cable to the voltage or current transmitter terminals. The initial confusion was decyphering between the different formats: Please contact us mi8 additional information.

Related Posts (10)  BANGSAMORO BASIC LAW DRAFT PDF

Cut foil shield and drain wire. It has a maximum backplane power consumption of 1 Watt at 5 Volts DC and 2. D Micro Programmable Logic Controllers. This makes it clear. It 146 be converted to digital operation with successive approximation and using the switched capacitor.

I did not see it in the NI8 user manual or installation manual. Connect shields for channels 0 through 3 to hi8 upper shield terminal and shields for channels 4 through 7 to the lower shield terminal. Complain wrong Brand wrong Model non readable. This is probably where the confusion came from. This end of the cable is connected to one of the shield terminals on the NI8 module.

Does this module have a terminal block?